Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 50.353
Filter
1.
Int J Mol Sci ; 25(9)2024 Apr 24.
Article in English | MEDLINE | ID: mdl-38731871

ABSTRACT

Implanted medical devices are widely used across various medical specialties for numerous applications, ranging from cardiovascular supports to orthopedic prostheses and cosmetic enhancements. However, recent observations have raised concerns about the potential of these implants to induce malignancies in the tissues surrounding them. There have been several case reports documenting the occurrence of cancers adjacent to these devices, prompting a closer examination of their safety. This review delves into the epidemiology, clinical presentations, pathological findings, and hypothesized mechanisms of carcinogenesis related to implanted devices. It also explores how the surgical domain and the intrinsic properties and biocompatibility of the implants might influence the development of these rare but serious malignancies. Understanding these associations is crucial for assessing the risks associated with the use of medical implants, and for developing strategies to mitigate potential adverse outcomes.


Subject(s)
Biocompatible Materials , Neoplasms , Prostheses and Implants , Humans , Biocompatible Materials/adverse effects , Prostheses and Implants/adverse effects , Neoplasms/etiology , Animals
2.
Vestn Oftalmol ; 140(2): 72-77, 2024.
Article in Russian | MEDLINE | ID: mdl-38742501

ABSTRACT

The modern treatment strategy for keratoconus (KC) involves sequential application of medical technologies aimed at stabilizing pathological changes in the cornea and restoring visual acuity. PURPOSE: This study compares the effect of implantation of intrastromal corneal ring segment (ICRS) and fitting of individual scleral rigid contact lenses (RCLs) on visual functions in patients with stage II-III KC after previously performed corneal collagen cross-linking. MATERIAL AND METHODS: The Helmholtz National Medical Research Center of Eye Diseases examined and treated 34 patients (69 eyes) aged 18 to 33 years with stage II-III KC. The study included patients who had previously undergone standard corneal collagen cross-linking. Depending on the type of optical correction, the patients were divided into two groups: patients in group 1 underwent ICRS implantation using a femtosecond laser; patients in group 2 were fitted with individual scleral RCLs. RESULTS: Improvement in clinical and functional parameters was observed in both groups. A higher clinical and functional result was achieved in group 2. CONCLUSION: For patients with stable stage II-III KC, it is advisable to recommend fitting of individual scleral RCLs for visual rehabilitation.


Subject(s)
Contact Lenses , Keratoconus , Sclera , Visual Acuity , Humans , Keratoconus/surgery , Keratoconus/diagnosis , Keratoconus/physiopathology , Keratoconus/therapy , Female , Male , Adult , Sclera/surgery , Prosthesis Implantation/methods , Prosthesis Implantation/instrumentation , Treatment Outcome , Corneal Topography , Prostheses and Implants , Young Adult , Prosthesis Fitting/methods , Adolescent , Corneal Stroma/surgery
3.
J Orthop Surg Res ; 19(1): 273, 2024 May 02.
Article in English | MEDLINE | ID: mdl-38698477

ABSTRACT

BACKGROUND: Talar malignant tumor is extremely rare. Currently, there are several alternative management options for talus malignant tumor including below-knee amputation, tibio-calcaneal arthrodesis, and homogenous bone transplant while their shortcomings limited the clinical application. Three-dimensional (3D) printed total talus prosthesis in talus lesion was reported as a useful method to reconstruct talus, however, most researches are case reports and its clinical effect remains unclear. Therefore, the current study was to explore the application of 3D printed custom-made modular prosthesis in talus malignant tumor. METHODS: We retrospectively analyzed the patients who received the 3D printed custom-made modular prosthesis treatment due to talus malignant tumor in our hospital from February 2016 to December 2021. The patient's clinical data such as oncology outcome, operation time, and volume of blood loss were recorded. The limb function was evaluated with the Musculoskeletal Tumor Society 93 (MSTS-93) score, The American Orthopedic Foot and Ankle Society (AOFAS) score; the ankle joint ranges of motion as well as the leg length discrepancy were evaluated. Plain radiography and Tomosynthesis-Shimadzu Metal Artefact Reduction Technology (T-SMART) were used to evaluate the position of prosthesis and the osseointegration. Postoperative complications were recorded. RESULTS: The average patients' age and the follow-up period were respectively 31.5 ± 13.1 years; and 54.8 months (range 26-72). The medium operation time was 2.4 ± 0.5 h; the intraoperative blood loss was 131.7 ± 121.4 ml. The mean MSTS-93 and AOFAS score was 26.8 and 88.5 respectively. The average plantar flexion, dorsiflexion, varus, and valgus were 32.5, 9.2, 10.8, and 5.8 degree respectively. One patient had delayed postoperative wound healing. There was no leg length discrepancy observed in any patient and good osseointegration was observed on the interface between the bone and talus prosthesis in all subjects. CONCLUSION: The modular structure of the prosthesis developed in this study seems to be convenient for prosthesis implantation and screws distribution. And the combination of solid and porous structure improves the initial stability and promotes bone integration. Therefore, 3D printed custom-made modular talus prosthesis could be an alternative option for talus reconstruction in talus malignant tumor patients.


Subject(s)
Bone Neoplasms , Printing, Three-Dimensional , Prosthesis Design , Talus , Humans , Talus/surgery , Talus/diagnostic imaging , Male , Adult , Female , Bone Neoplasms/surgery , Bone Neoplasms/diagnostic imaging , Retrospective Studies , Middle Aged , Young Adult , Prosthesis Implantation/methods , Prosthesis Implantation/instrumentation , Adolescent , Ankle Joint/surgery , Ankle Joint/diagnostic imaging , Osseointegration , Treatment Outcome , Range of Motion, Articular , Prostheses and Implants
4.
Nat Commun ; 15(1): 4017, 2024 May 13.
Article in English | MEDLINE | ID: mdl-38740759

ABSTRACT

Ultrasound-driven bioelectronics could offer a wireless scheme with sustainable power supply; however, current ultrasound implantable systems present critical challenges in biocompatibility and harvesting performance related to lead/lead-free piezoelectric materials and devices. Here, we report a lead-free dual-frequency ultrasound implants for wireless, biphasic deep brain stimulation, which integrates two developed lead-free sandwich porous 1-3-type piezoelectric composite elements with enhanced harvesting performance in a flexible printed circuit board. The implant is ultrasonically powered through a portable external dual-frequency transducer and generates programmable biphasic stimulus pulses in clinically relevant frequencies. Furthermore, we demonstrate ultrasound-driven implants for long-term biosafety therapy in deep brain stimulation through an epileptic rodent model. With biocompatibility and improved electrical performance, the lead-free materials and devices presented here could provide a promising platform for developing implantable ultrasonic electronics in the future.


Subject(s)
Deep Brain Stimulation , Wireless Technology , Deep Brain Stimulation/instrumentation , Deep Brain Stimulation/methods , Animals , Wireless Technology/instrumentation , Rats , Electrodes, Implanted , Epilepsy/therapy , Male , Prostheses and Implants , Rats, Sprague-Dawley , Transducers , Equipment Design , Ultrasonic Waves
5.
Article in English | MEDLINE | ID: mdl-38723798

ABSTRACT

Wearable and implantable sensing of biomechanical signals such as pressure, strain, shear, and vibration can enable a multitude of human-integrated applications, including on-skin monitoring of vital signs, motion tracking, monitoring of internal organ condition, restoration of lost/impaired mechanoreception, among many others. The mechanical conformability of such sensors to the human skin and tissue is critical to enhancing their biocompatibility and sensing accuracy. As such, in the recent decade, significant efforts have been made in the development of soft mechanical sensors. To satisfy the requirements of different wearable and implantable applications, such sensors have been imparted with various additional properties to make them better suited for the varied contexts of human-integrated applications. In this review, focusing on the four major types of soft mechanical sensors for pressure, strain, shear, and vibration, we discussed the recent material and device design innovations for achieving several important properties, including flexibility and stretchability, bioresorbability and biodegradability, self-healing properties, breathability, transparency, wireless communication capabilities, and high-density integration. We then went on to discuss the current research state of the use of such novel soft mechanical sensors in wearable and implantable applications, based on which future research needs were further discussed. This article is categorized under: Diagnostic Tools > Biosensing Diagnostic Tools > Diagnostic Nanodevices Implantable Materials and Surgical Technologies > Nanomaterials and Implants.


Subject(s)
Prostheses and Implants , Wearable Electronic Devices , Humans , Equipment Design , Biosensing Techniques/instrumentation , Monitoring, Physiologic/instrumentation
6.
Transl Vis Sci Technol ; 13(5): 2, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38696181

ABSTRACT

Purpose: Currently, no solution exists to restore natural eyelid kinematics for patients with complete eyelid paralysis due to loss of function of both the levator palpebrae superioris and orbicularis oculi. These rare cases are prone to complications of chronic exposure keratopathy which may lead to corneal blindness. We hypothesized that magnetic force could be used to fully automate eyelid movement in these cases through the use of eyelid-attached magnets and a spectacle-mounted magnet driven by a programmable motor (motorized magnetic levator prosthesis [MMLP]). Methods: To test this hypothesis and establish proof of concept, we performed a finite element analysis (FEA) for a prototype MMLP to check the eyelid-opening force generated by the device and verified the results with experimental measurements in a volunteer with total bidirectional eyelid paralysis. The subject was then fitted with a prototype to check the performance of the device and its success. Results: With MMLP, eye opening was restored to near normal, and blinking was fully automated in close synchrony with the motor-driven polarity reversal, with full closure on the blink. The device was well tolerated, and the participant was pleased with the comfort and performance. Conclusions: FEA simulation results conformed to the experimentally observed trend, further supporting the proof of concept and design parameters. This is the first viable approach in human patients with proof of concept for complete reanimation of a bidirectionally paretic eyelid. Further study is warranted to refine the prototype and determine the feasibility and safety of prolonged use. Translational Relevance: This is first proof of concept for our device for total bidirectional eyelid paralysis.


Subject(s)
Blinking , Eyelids , Proof of Concept Study , Humans , Blinking/physiology , Eyelids/physiopathology , Eyelid Diseases/physiopathology , Eyelid Diseases/therapy , Oculomotor Muscles/physiopathology , Finite Element Analysis , Biomechanical Phenomena , Prostheses and Implants , Prosthesis Design , Magnets , Male
7.
Article in English | MEDLINE | ID: mdl-38716831

ABSTRACT

BACKGROUND: Patients with persistent air leak (PAL) pose a therapeutic challenge to physicians, with prolonged hospital stays and high morbidity. There is little evidence on the efficacy and safety of bronchial valves (BV) for PAL. METHODS: We systematically searched the PubMed and Embase databases to identify studies evaluating the efficacy and safety of BV for PAL. We calculated the success rate (complete resolution of air leak or removal of intercostal chest drain after bronchial valve placement and requiring no further procedures) of BV for PAL in individual studies. We pooled the data using a random-effects model and examined the factors influencing the success rate using multivariable meta-regression. RESULTS: We analyzed 28 observational studies (2472 participants). The pooled success rate of bronchial valves in PAL was 82% (95% confidence intervals, 75 to 88; 95% prediction intervals, 64 to 92). We found a higher success rate in studies using intrabronchial valves versus endobronchial valves (84% vs. 72%) and in studies with more than 50 subjects (93% vs. 77%). However, none of the factors influenced the success rate of multivariable meta-regression. The overall complication rate was 9.1% (48/527). Granulation tissue was the most common complication reported followed by valve migration or expectoration and hypoxemia. CONCLUSION: Bronchial valves are an effective and safe option for treating PAL. However, the analysis is limited by the availability of only observational data.


Subject(s)
Pneumothorax , Humans , Pneumothorax/etiology , Bronchi , Treatment Outcome , Postoperative Complications/epidemiology , Chest Tubes/adverse effects , Prostheses and Implants/adverse effects , Bronchoscopy/methods , Bronchoscopy/adverse effects , Observational Studies as Topic
8.
Medicine (Baltimore) ; 103(18): e37932, 2024 May 03.
Article in English | MEDLINE | ID: mdl-38701315

ABSTRACT

Angiosarcomas are rare and highly malignant soft tissue sarcomas originating from endothelial cells lining the lymphatic or vascular system. While they predominantly emerge from (sub)cutaneous regions, occurrences have been reported throughout the body. The etiology of angiosarcoma remains elusive in most clinical cases. Nevertheless, several prognosis risk factors play a pivotal role, including chronic lymphedema, therapeutic irradiation, environmental carcinogens, familial syndromes, and the presence of foreign materials like metallic objects and biomedical implants. Despite evidence implicating retained foreign material in angiosarcoma development, understanding its prognosis and pathogenesis remains limited. The pathogenesis of angiosarcoma appears to involve a complex interplay of chronic inflammation, tissue remodeling, and genetic factors that create a conducive microenvironment for malignant transformation. Management of these sarcomas remains challenging due to their infiltrative nature owing to the high chance of metastasis and local recurrence. The primary treatment modalities currently include surgery, radiotherapy, and chemotherapy, but recent advances in targeted immunotherapy and gene therapy hold promise for more effective approaches. This comprehensive review delves into the potential etiological and pathogenic roles of foreign materials, such as metallic objects, biomedical implants, and biomaterials, in the development of angiosarcoma. Further research into the underlying molecular mechanisms could provide valuable insights for tailored management and developing novel targeted therapeutic strategies.


Subject(s)
Foreign Bodies , Hemangiosarcoma , Prostheses and Implants , Humans , Hemangiosarcoma/therapy , Hemangiosarcoma/etiology , Hemangiosarcoma/pathology , Foreign Bodies/complications , Foreign Bodies/therapy , Prostheses and Implants/adverse effects , Risk Factors
9.
Harefuah ; 163(5): 310-314, 2024 May.
Article in Hebrew | MEDLINE | ID: mdl-38734945

ABSTRACT

INTRODUCTION: Corneal disease is among the leading reversible causes of blindness worldwide. Corneal transplantation is a successful and curative treatment for most of these cases. However, in certain indications it is not amendable for standard corneal transplantation, the only available option to restore functional vision is keratoprosthesis (KPro) implantation. KPros may also offer an alternative to the global shortage of donor corneas, limiting the access to transplantations. However, current KPros face many challenges, including surgical complexity that requires skilled surgeons and vast resources as well as unique surgical and post-operative complications. Although several artificial corneas have been proposed over the years, two implants are mostly used in the clinical setting today. The first, the Boston KPro, consists of a front plate with an optical stem and a back plate snapped together with donor corneal tissue in-between, which is then sutured to the patient's cornea. The second, the Osteo-odonto-keratoprosthesis (OOKP), uses biological tissue of the alveolar bone to support an optical cylinder within the eye. The indications, surgical techniques, and complication profile of the two procedures are different and will be discussed in this review. Extensive research continues to improve the accessibility and technological developments of KPros in the search for a potential breakthrough in the treatment of these difficult cases.


Subject(s)
Cornea , Corneal Diseases , Corneal Transplantation , Prostheses and Implants , Humans , Corneal Diseases/surgery , Corneal Transplantation/methods , Cornea/surgery , Artificial Organs , Blindness/etiology , Postoperative Complications
10.
Vestn Oftalmol ; 140(2. Vyp. 2): 166-171, 2024.
Article in Russian | MEDLINE | ID: mdl-38739147

ABSTRACT

Loading of the upper eyelid with palpebral implants made of noble metals is the modern standard of surgical treatment for paralytic lagophthalmos, and is aimed at increasing the mobility of the upper eyelid and normalizing involuntary blinking movements. This review presents the results of morphological studies, including immunohistochemical studies, reflecting the features of biointegration of palpebral implants in uncomplicated and complicated course of the postoperative period, and describes the modern understanding of the causes and immunopathological processes underlying the development of nonspecific inflammatory response, which is one of the most serious complications that often becomes an indication for implant removal.


Subject(s)
Eyelids , Humans , Eyelids/surgery , Eyelid Diseases/surgery , Metals , Prostheses and Implants , Blepharoplasty/methods , Prosthesis Design
11.
ACS Biomater Sci Eng ; 10(5): 3255-3267, 2024 May 13.
Article in English | MEDLINE | ID: mdl-38684056

ABSTRACT

Osteoporosis is a metabolic disease characterized by bone density and trabecular bone loss. Bone loss may affect dental implant osseointegration in patients with osteoporosis. To promote implant osseointegration in osteoporotic patients, we further used a nonthermal atmospheric plasma (NTAP) treatment device previously developed by our research group. After the titanium implant (Ti) is placed into the device, the working gas flow and the electrode switches are turned on, and the treatment is completed in 30 s. Previous studies showed that this NTAP device can remove carbon contamination from the implant surface, increase the hydroxyl groups, and improve its wettability to promote osseointegration in normal conditions. In this study, we demonstrated the tremendous osteogenic enhancement effect of NTAP-Ti in osteoporotic conditions in rats for the first time. Compared to Ti, the proliferative potential of osteoporotic bone marrow mesenchymal stem cells on NTAP-Ti increased by 180% at 1 day (P = 0.004), while their osteogenic differentiation increased by 149% at 14 days (P < 0.001). In addition, the results indicated that NTAP-Ti significantly improved osseointegration in osteoporotic rats in vivo. Compared to the Ti, the bone volume fraction (BV/TV) and trabecular number (Tb.N) values of NTAP-Ti in osteoporotic rats, respectively, increased by 18% (P < 0.001) and 25% (P = 0.007) at 6 weeks and the trabecular separation (Tb.Sp) value decreased by 26% (P = 0.02) at 6 weeks. In conclusion, this study proved a novel NTAP irradiation titanium implant that can significantly promote osseointegration in osteoporotic conditions.


Subject(s)
Mesenchymal Stem Cells , Osseointegration , Osteogenesis , Osteoporosis , Plasma Gases , Rats, Sprague-Dawley , Titanium , Titanium/pharmacology , Animals , Osteogenesis/drug effects , Osteoporosis/pathology , Osteoporosis/therapy , Osteoporosis/drug therapy , Plasma Gases/pharmacology , Plasma Gases/therapeutic use , Osseointegration/drug effects , Female , Rats , Mesenchymal Stem Cells/drug effects , Cell Differentiation/drug effects , Cell Proliferation/drug effects , Prostheses and Implants
12.
Colloids Surf B Biointerfaces ; 238: 113891, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38615392

ABSTRACT

The three-dimensional-printed Ti6Al4V implant (3DTi) has been widely accepted for the reconstruction of massive bone defects in orthopedics owing to several advantages, such as its tailored shape design, avoiding bone graft and superior bone-implant interlock. However, the osteoinduction activity of 3DTi is inadequate when applied clinically even though it exhibits osteoconduction. This study developes a comprehensive coatless strategy for the surface improvement of 3DTi through copper (Cu) ion implantation and ultraviolet (UV) photofunctionalization to enhance osteoinductivity. The newly constructed functional 3DTi (UV/Ti-Cu) achieved stable and controllable Cu doping, sustained Cu2+ releasing, and increased surface hydrophilicity. By performing cellular experiments, we determined that the safe dose range of Cu ion implantation was less than 5×1016 ions/cm2. The implanted Cu2+ enhanced the ALP activity and the apatite formation ability of bone marrow stromal cells (BMSCs) while slightly decreasing proliferation ability. When combined with UV photofunctionalization, cell adhesion and proliferation were significantly promoted and bone mineralization was further increased. Meanwhile, UV/Ti-Cu was conducive to the migration and angiogenesis of human umbilical vein endothelial cells (HUVECs) in vitro, theoretically facilitating vascular coupling osteogenesis. In conclusion, UV/Ti-Cu is a novel attempt to apply two coatless techniques for the surface modification of 3DTi. In addition, it is considered a potential bone substrate for repairing bone defects.


Subject(s)
Alloys , Cell Adhesion , Copper , Human Umbilical Vein Endothelial Cells , Neovascularization, Physiologic , Osteogenesis , Printing, Three-Dimensional , Titanium , Ultraviolet Rays , Titanium/chemistry , Titanium/pharmacology , Alloys/chemistry , Alloys/pharmacology , Osteogenesis/drug effects , Copper/chemistry , Copper/pharmacology , Cell Adhesion/drug effects , Humans , Human Umbilical Vein Endothelial Cells/drug effects , Neovascularization, Physiologic/drug effects , Animals , Mesenchymal Stem Cells/cytology , Mesenchymal Stem Cells/drug effects , Surface Properties , Ions/chemistry , Cell Proliferation/drug effects , Prostheses and Implants , Cells, Cultured , Angiogenesis
13.
JBJS Case Connect ; 14(2)2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38635765

ABSTRACT

CASE: We present 2 cases of severe hemodynamic collapse during prophylactic stabilization of impending pathologic humerus fractures using a photodynamic bone stabilization device. Both events occurred when the monomer was infused under pressure into a balloon catheter. CONCLUSION: We suspect that an increase in intramedullary pressure during balloon expansion may cause adverse systemic effects similar to fat embolism or bone cement implantation syndrome. Appropriate communication with the anesthesia team, invasive hemodynamic monitoring, and prophylactic vent hole creation may help mitigate or manage these adverse systemic effects.


Subject(s)
Embolism, Fat , Fractures, Spontaneous , Vascular Diseases , Humans , Fractures, Spontaneous/etiology , Humerus/surgery , Humerus/pathology , Embolism, Fat/etiology , Prostheses and Implants/adverse effects
14.
Cells ; 13(8)2024 Apr 09.
Article in English | MEDLINE | ID: mdl-38667271

ABSTRACT

Even with the best infection control protocols in place, the risk of a hospital-acquired infection of the surface of an implanted device remains significant. A bacterial biofilm can form and has the potential to escape the host immune system and develop resistance to conventional antibiotics, ultimately causing the implant to fail, seriously impacting patient well-being. Here, we demonstrate a 4 log reduction in the infection rate by the common pathogen S. aureus of 3D-printed polyaryl ether ketone (PAEK) polymeric surfaces by covalently binding the antimicrobial peptide Mel4 to the surface using plasma immersion ion implantation (PIII) treatment. The surfaces with added texture created by 3D-printed processes such as fused deposition-modelled polyether ether ketone (PEEK) and selective laser-sintered polyether ketone (PEK) can be equally well protected as conventionally manufactured materials. Unbound Mel4 in solution at relevant concentrations is non-cytotoxic to osteoblastic cell line Saos-2. Mel4 in combination with PIII aids Saos-2 cells to attach to the surface, increasing the adhesion by 88% compared to untreated materials without Mel4. A reduction in mineralisation on the Mel4-containing surfaces relative to surfaces without peptide was found, attributed to the acellular portion of mineral deposition.


Subject(s)
Antimicrobial Peptides , Benzophenones , Polymers , Printing, Three-Dimensional , Prostheses and Implants , Staphylococcus aureus , Humans , Staphylococcus aureus/drug effects , Antimicrobial Peptides/pharmacology , Antimicrobial Peptides/chemistry , Antimicrobial Peptides/metabolism , Prostheses and Implants/adverse effects , Polymers/chemistry , Polymers/pharmacology , Biofilms/drug effects , Ketones/chemistry , Ketones/pharmacology , Osteoblasts/drug effects , Osteoblasts/metabolism , Polyethylene Glycols/chemistry , Polyethylene Glycols/pharmacology , Surface Properties , Bone and Bones/drug effects , Bone and Bones/metabolism , Orthopedics
15.
Biomaterials ; 308: 122576, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38640785

ABSTRACT

Biomaterial-associated infection (BAI) is considered a unique infection due to the presence of a biomaterial yielding frustrated immune-cells, ineffective in clearing local micro-organisms. The involvement of surface-adherent/surface-adapted micro-organisms in BAI, logically points to biomaterial surface-modifications for BAI-control. Biomaterial surface-modification is most suitable for prevention before adhering bacteria have grown into a mature biofilm, while BAI-treatment is virtually impossible through surface-modification. Hundreds of different surface-modifications have been proposed for BAI-control but few have passed clinical trials due to the statistical near-impossibility of benefit-demonstration. Yet, no biomaterial surface-modification forwarded, is clinically embraced. Collectively, this leads us to conclude that surface-modification is a dead-end road. Accepting that BAI is, like most human infections, due to surface-adherent biofilms (though not always to a foreign material), and regarding BAI as a common infection, opens a more-generally-applicable and therewith easier-to-validate road. Pre-clinical models have shown that stimuli-responsive nano-antimicrobials and antibiotic-loaded nanocarriers exhibit prolonged blood-circulation times and can respond to a biofilm's micro-environment to penetrate and accumulate within biofilms, prompt ROS-generation and synergistic killing with antibiotics of antibiotic-resistant pathogens without inducing further antimicrobial-resistance. Moreover, they can boost frustrated immune-cells around a biomaterial reducing the importance of this unique BAI-feature. Time to start exploring the nano-road for BAI-control.


Subject(s)
Biocompatible Materials , Biofilms , Nanotechnology , Surface Properties , Humans , Biocompatible Materials/chemistry , Biofilms/drug effects , Nanotechnology/methods , Animals , Prosthesis-Related Infections/prevention & control , Prostheses and Implants , Anti-Bacterial Agents/pharmacology , Anti-Bacterial Agents/therapeutic use
17.
Biosens Bioelectron ; 257: 116302, 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-38648705

ABSTRACT

This review article focuses on the recent printing technological progress in healthcare, underscoring the significant potential of implantable devices across diverse applications. Printing technologies have widespread use in developing health monitoring devices, diagnostic systems, and surgical devices. Recent years have witnessed remarkable progress in fabricating low-profile implantable devices, driven by advancements in printing technologies and nanomaterials. The importance of implantable biosensors and bioelectronics is highlighted, specifically exploring printing tools using bio-printable inks for practical applications, including a detailed examination of fabrication processes and essential parameters. This review also justifies the need for mechanical and electrical compatibility between bioelectronics and biological tissues. In addition to technological aspects, this article delves into the importance of appropriate packaging methods to enhance implantable devices' performance, compatibility, and longevity, which are made possible by integrating cutting-edge printing technology. Collectively, we aim to shed light on the holistic landscape of implantable biosensors and bioelectronics, showcasing their evolving role in advancing healthcare through innovative printing technologies.


Subject(s)
Biosensing Techniques , Prostheses and Implants , Biosensing Techniques/instrumentation , Humans , Electronics/instrumentation , Printing, Three-Dimensional , Equipment Design , Nanostructures/chemistry , Delivery of Health Care/trends
18.
Proc Inst Mech Eng H ; 238(5): 550-561, 2024 May.
Article in English | MEDLINE | ID: mdl-38627994

ABSTRACT

The designed biomedical implants require excellent shear strength primarily for mechanical stability against forces in human body. However, metallic implants undergo stress shielding with release of toxic ions in the body. Thus, Fused Deposition Modeling (FDM) has made significant progress in the biomedical field through the production of customized implants. The mechanical behavior is highly dependent on printing parameters, however, the effect of these parameters on punch shear strength of ASTM D732-02 standard specimens has not been explored. Thus, in the current study, the effect of infill density (IFD), printing speed (PTS), wall thickness (WLT), and layer thickness (LYT) has been investigated on the punch shear strength using Response Surface Methodology. The Analysis of Variance (ANOVA) has been performed for predicting statistical model with 95% confidence interval. During the statistical analysis, the terms with p-value lower than 0.05 were considered significant and the influence of process parameters has been examined using microscopic images. The surface plots have been used for discussing the effect of interactions between printing parameters. The statistical results revealed IFD as the most significant contributing factor, followed by PTS, LYT, and WLT. The study concluded by optimization of printing parameters for obtaining the highest punch shear strength.


Subject(s)
Materials Testing , Polyesters , Shear Strength , Polyesters/chemistry , Prostheses and Implants , Stress, Mechanical , Printing, Three-Dimensional
20.
Angiol. (Barcelona) ; 76(2): 109-112, Mar-Abr. 2024. ilus
Article in Spanish | IBECS | ID: ibc-232386

ABSTRACT

Introducción: la infección de prótesis aórtica en la cirugía vascular convencional es un evento catastrófico, con una alta tasa de morbilidad y de mortalidad. El tratamiento tradicional ha sido la remoción de la prótesis y la reconstrucción con bypass extraanatómico. En algunos casos, se ha llevado a cabo el reemplazo con prótesis impregnadas en antibiótico; en otros, el reemplazo con vena femoral superficial y también la cirugía abierta con drenaje de las colecciones asociadas y antibioticoterapia de por vida. Caso clínico: se presenta el reporte de un caso de infección protésica tratada con drenajes de las colecciones y antibioticoterapia de larga duración, con un resultado favorable un año después de su complicación. Discusión: en algunos casos, dada la severidad del paciente, es posible intentar un tratamiento conservador de esta nefasta complicación.(AU)


Introduction: in traditional vascular surgery, aortic prosthesis infection is a catastrophic event with high morbidity andmortality rates. Traditional treatment is the removal of the valve followed by extra-anatomic bypass reconstruction. Insome cases, antibiotic-impregnated prosthesis replacement has been performed. In others, superficial femoral veinreplacement, and open surgery with drainage of the associated collections and lifelong antibiotic therapy.Case report: this is the case of a patient with aortic prosthesis infection undergoing draining collections and lifelongantibiotic therapy with a favorable outcome 1 year after the complication.Discussion: in some cases, given the severity of the patient, we can try to treat this dreaded complication conservativel.(AU)


Subject(s)
Humans , Male , Aged , Complementary Therapies , Prostheses and Implants/adverse effects , Prosthesis-Related Infections/drug therapy
SELECTION OF CITATIONS
SEARCH DETAIL
...